-40%
TPI 717 Flue Gas Combustion Analyzer with Smart Sensors
$ 316.78
- Description
- Size Guide
Description
AUTHORIZED DISTRIBUTORThe TPI 717 Combustion Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other desirable parameters associated with appliance installation and maintenance.
Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on.
Combustion Efficiency Analyzer:
Measure O2, CO, and flue temperature. Calculate efficiency, excess air, CO2 & (CO/CO2) Ratio.
CO Analyzer:
Measure carbon monoxide in ambient air.
Differential Manometer:
+/- 150 mBar (0.01 mBar resolution). Great for tightness/let by or burner pressure testing.
Differential Thermometer:
Dual input K-Type thermocouple thermometer measures differential temperatures. Ideal for measuring & recording flow & return temperatures.
Integrated Magnet
for hands-free use;
Push on fittings
for fast and easy use
11 Selectable fuels
The TPI 717 combustion analyzer
is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion. The instrument is ruggedly constructed and comes with a 3 Year unit and 2 Year sensor Guarantee.
What's in the box:
TPI 717 Instrument
Rubber Boot (A765)
Soft Carrying Case (A768)
Flue Sampling Probe (A770)
In-Line Filter assembly installed on Flue probe (A796)
Temperature Probe (GK11M)
Mini Pump Protection Filter Assembly and spare filters (A763)
Exhaust Spigot (removable) (A764)
Instruction Manual
The TPI 717 Flue Gas Analyzer has the following options available:
Infrared Printer (A740)
Spare In-Line Filter (A762F is a package of 5 filters)
Field replaceable smart CO sensor (A760S)
Field replaceable smart O2 sensor (A761S)
TPI 717 Offers
Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on.
Features
Combustion Efficiency Analyzer: Measure O2, CO, and flue temperature. Calculate efficiency, excess air, CO2 & (CO/CO2) Ratio.
CO Analyzer: Measure carbon monoxide in ambient air.
Differential Manometer: +/- 150 mBar (0.01 mBar resolution). Great for tightness/let by or burner pressure testing.
Differential Thermometer: Dual input K-Type thermocouple thermometer measures differential temperatures. Ideal for measuring & recording flow & return temperatures.
Integrated Magnet for hands-free use; Push on fittings for fast and easy use
Applications
Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers.
Model 717 Specifications
Instrument
Operating Temperature Range
14°F to +122°F (-10°C to +50°C)
Battery / Batery Life
Rechargeable Ni-MH / > 6 Hours
Charger Input Voltage
115V or 230V : 50/60 Hz AC
Fuels
Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
Anthracite Coal, Coke, Butane, Wood, Bagasse
Pressure Ranges
mbar, kPa & inH2O
Display
Backlit Graphic LCD
Data Storage
50 sets of readings, multiple pages
Time and Date
24 Hour Real Time Clock
Dimensions
200mm x 90mm x 60mm
Weight
500g
Casing
Rubber Boot as Standard
Switch Off
Failsafe
Exhaust
Safety Spigot
Conforms to
EN50379
Flue Temperature Probe
Construction
Pistol Grip with Stainless Steel Shaft
Hose Length
2500mm
Insertion Length
200mm
'K' Type Thermocouple Accuracy
+/- 0.3%, +/- 1˚C
Maximum Temperature
800°C
Gases
Range
Resolution
Accuracy
Oxygen
0-25%
0.1%
+/- 0.3%
Carbon Monoxide
0-10,000 ppm
1 ppm
<20ppm +/- 3 ppm
>100ppm +/- 5%
Carbon Dioxide (calculated)
0-25%
0.1%
+/- 0.3%
Combustion Efficiency
0-100%
0.1%
Pressure Measurement
Selectable Ranges
mbar, kPa and inH2O
Range
- 150 mbar to + 150 mbar
Resolution
0.01 mbar & 0.1 mbar
Accuracy
+/- 0.5% fsd
Frequently Asked Questions
Can I use my analyzer on Oil Fired Appliances?
Yes.
Please ensure that the analyzer is set to the correct fuel and that the additional oil filter (A773) is fitted. It is also recommended to use a smoke pump before performing any analyzer test.
NOTE:
Do not use the A773 oil filter if an NO/NOx sensor is fitted
Can I use my analyzer to perform Tightness Tests?
Yes.
All TPI Flue Gas Analyzer models have pressure which will allow all types of pressure testing to be performed; the 716 has in-built software which makes Tightness Testing even easier to perform.
Can I read Flow & Return Temperatures with a TPI Analyzer?
Yes.
All TPI Flue Gas Analyzer models have Differential Temperature (Dual Inputs) which enables 2 temperatures to be taken at the same time and the difference calculated and displayed.